Henkel LOCTITE 97504 User Manual Page 75

  • Download
  • Add to my manuals
  • Print
  • Page
    / 94
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 74
75
3 Operation
3.8.5 Enter calibration factor
The capacity of pump B is calibrated to ensure accurate control and consistency of
Part A and Part B mixing ratios.
The capacity of pump A is the reference value (100%). For determination of the
calibration factor proceed as described in Section 3.4.
Enter calibration factor:
With the dispensing station in ready state, push * button twice - display indicates
Enter password.
Enter password, see Section 3.8.1.
Push OK button three times - display indicates Calibration factor.
Use arrow keys to enter desired value.
Arrow key assignment / setting range:
left: -10; right: +10; up: +1;
down: -1; setting range: 70 – 140.
• Push OK button to save the setting – display indicates "next menu item". Push
ESC key to leave the service menu – display indicates Operation.
3.8.6 Select User Interface language
Messages can be displayed in German or in English.
Interface language setup:
With the dispensing station in ready state, push * button twice - display indicates
Enter password.
Enter password, see Section 3.8.1.
• Push OK button 4 times - display indicates Language selection
or
The following languages can be
adjusted:
– Deutsch
– French
– Italian
– Portuguese
Use arrow keys to enter desired value.
Arrow key assignment / setting range: left: German; right: English
• Push OK button to save the setting – display indicates "next menu item". Push
ESC key to leave the service menu – display indicates Operation.
Language
english
OK/ESC
Adjustment
105 %
OK/ESC
Page view 74
1 2 ... 70 71 72 73 74 75 76 77 78 79 80 ... 93 94

Comments to this Manuals

No comments